1827 N Grant St
1827 N Grant St is a 14-story condominium building in Greater Downtown Denver. Its floor plate has 95% of its area within daylight reach of a facade and scores 90 out of 100 on this screen’s measures, which is part of why it works as housing.
CO-1 · Screened 2026-09-19 · Already housing
Where 1827 N Grant St is
Its block in Greater Downtown Denver, drawn from Denver's own building outlines and street centerlines.
- Already housing
- Not screened
- 1827 N Grant St
This is already a condominium building: Denver's property records list 110 condominiums here. It is on the map because the city's building outlines file it as commercial, but this site does not count it as a conversion candidate.
Across its 13 residential floors this building carries 6,047 sq ft of windowless core — area that must be gutted, re-plumbed and sprinklered but can never be rented as an apartment.
Modeled conversion metrics for 1827 N Grant St, 2026-09-19.
| Suitability scoreStrong candidate | 90 / 100 |
|---|---|
| Storiesfrom 163 ft aerial-survey height ÷ 12 ft floor-to-floor | 14 |
| Height bandsfloor plate by floor range, from the city's roof outlines | Floor 1: 16,508 sq ft · Floor 2: 15,585 sq ft · Floor 3: 9,821 sq ft · Floors 4–13: 9,413 sq ft · Floor 14: 866 sq ft |
| Floor platetypical floor, from the city outlines | 9,413 sq ft |
| Daylight efficiencyshare within 35 ft of a facade | 95% |
| Deepest interior pointviability threshold is 80 ft | 44 ft |
| Windowless coretypical floor; the building-wide total is in the text above | 382 sq ft |
| BuiltDenver does not publish a construction year with this data | — |
| ZoningNorth Capitol Hill | C-MX-12 |
| Opportunity Zonenot in a 2018 designated tract | No |
The plan: window line, shape and floor rhythm
48 ft of exterior wall for each home the screen estimates — enough for two- and three-bedroom homes across the plan.
The typical floor has 458 ft of exterior wall, and across 13 residential floors the building carries 5,763 ft of it in total, divided among the 121 homes this screen estimates.
Its plate is moderately compact at 0.56: a squarish plan, with enough perimeter for a conventional double-loaded corridor. How window line and plate shape are measured.
At the model’s 750 sq ft average, the plan works out at about 9.3 homes per floor. Its floors are not alike, though: the typical floor's deepest interior point is 44 ft from a facade, while its worst floor reaches 47 ft. The score follows the typical floor, so a podium that could not hold a bedroom does not by itself sink a slim tower above it — but it is there, and it is part of what would have to be drawn around.
Why 1827 N Grant St scores 90 out of 100
Daylight efficiency 100, Interior depth 90, Scale 81, Finance 71 — each out of 100, then weighted.
Score components for 1827 N Grant St. Points are the subscore times its weight.
| Component | Subscore | Weight | Points |
|---|---|---|---|
| Daylight efficiency95% of the floor area within 35 ft of a facade, scored from 40% up to 90% | 100 | 45% | 45.0 |
| Interior depthdeepest interior point 44 ft from a facade, scored from 80 ft down to 40 ft | 90 | 25% | 22.5 |
| Scale121 estimated homes, scored from 0 up to 150 | 81 | 15% | 12.1 |
| Financeremaining gap is 17% of conversion cost, scored from 60% down to 0% | 71 | 15% | 10.7 |
Most of what it earns comes from daylight efficiency, and what holds it back most is finance, at 71 out of 100: remaining gap is 17% of conversion cost, scored from 60% down to 0%.
Other buildings screened near 1827 N Grant St
The 4 closest the screen also covers, from 190 ft away. They are the colored outlines on the plan at the top of this page.
- 1888 N Sherman St9 stories · 90% daylit · 69 estimated homes · scores 79/100 (Strong candidate)about 190 ft away
- 1800 N Grant St10 stories · 85% daylit · 121 estimated homes · scores 82/100 (Strong candidate)about 240 ft away
- 1845 N Sherman St8 stories · 79% daylit · 90 estimated homes · scores 63/100 (Worth a feasibility study)about 350 ft away
- 1901 N Grant St11 stories · 88% daylit · already an apartment buildingabout 360 ft away
A screen, not a feasibility study, from outlines and heights rather than plans: the method and how to correct a figure. If you know this building’s interior, you know what this model cannot see.