3100 N Huron St
3100 N Huron St is a 6-story condominium building in Greater Downtown Denver. Its floor plate has 94% of its area within daylight reach of a facade and scores 86 out of 100 on this screen’s measures, which is part of why it works as housing.
CO-1 · Screened 2026-09-19 · Already housing
Where 3100 N Huron St is
Its block in Greater Downtown Denver, drawn from Denver's own building outlines and street centerlines.
- Already housing
- Not screened
- 3100 N Huron St
This is already a condominium building: Denver's property records list 120 condominiums here. It is on the map because the city's building outlines file it as commercial, but this site does not count it as a conversion candidate.
Across its 5 residential floors this building carries 5,744 sq ft of windowless core — area that must be gutted, re-plumbed and sprinklered but can never be rented as an apartment.
Modeled conversion metrics for 3100 N Huron St, 2026-09-19.
| Suitability scoreStrong candidate | 86 / 100 |
|---|---|
| Storiesfrom 71 ft aerial-survey height ÷ 12 ft floor-to-floor | 6 |
| Height bandsfloor plate by floor range, from the city's roof outlines | Floor 1: 29,544 sq ft · Floors 2–4: 25,220 sq ft · Floor 5: 20,483 sq ft · Floor 6: 1,053 sq ft |
| Floor platetypical floor, from the city outlines | 25,220 sq ft |
| Daylight efficiencyshare within 35 ft of a facade | 94% |
| Deepest interior pointviability threshold is 80 ft | 47 ft |
| Windowless coretypical floor; the building-wide total is in the text above | 1,635 sq ft |
| BuiltDenver does not publish a construction year with this data | — |
| ZoningFive Points | R-MU-30 |
| Opportunity Zonenot in a 2018 designated tract | No |
The plan: window line, shape and floor rhythm
45 ft of exterior wall for each home the screen estimates — enough for two- and three-bedroom homes across the plan.
The typical floor has 1,032 ft of exterior wall, and across 5 residential floors the building carries 4,387 ft of it in total, divided among the 97 homes this screen estimates.
Its plate is elongated at 0.30: a slab or an L, which is why so much of the floor lies within reach of a window: the outline buys daylight that a square plan of the same area would not. How window line and plate shape are measured.
At the model’s 750 sq ft average, the plan works out at about 19.4 homes per floor. Its floors are not alike, though: the typical floor's deepest interior point is 47 ft from a facade, while its worst floor reaches 61 ft. The score follows the typical floor, so a podium that could not hold a bedroom does not by itself sink a slim tower above it — but it is there, and it is part of what would have to be drawn around.
Why 3100 N Huron St scores 86 out of 100
Daylight efficiency 100, Interior depth 82, Scale 65, Finance 70 — each out of 100, then weighted.
Score components for 3100 N Huron St. Points are the subscore times its weight.
| Component | Subscore | Weight | Points |
|---|---|---|---|
| Daylight efficiency94% of the floor area within 35 ft of a facade, scored from 40% up to 90% | 100 | 45% | 45.0 |
| Interior depthdeepest interior point 47 ft from a facade, scored from 80 ft down to 40 ft | 82 | 25% | 20.4 |
| Scale97 estimated homes, scored from 0 up to 150 | 65 | 15% | 9.7 |
| Financeremaining gap is 18% of conversion cost, scored from 60% down to 0% | 70 | 15% | 10.5 |
Most of what it earns comes from daylight efficiency, and what holds it back most is scale, at 65 out of 100: 97 estimated homes, scored from 0 up to 150.
Other buildings screened near 3100 N Huron St
The 4 closest the screen also covers, from 390 ft away. They are the colored outlines on the plan at the top of this page.
- 3001 N Fox St5 stories · 88% daylit · already an apartment buildingabout 390 ft away
- 2900 N Fox St8 stories · 70% daylit · 176 estimated homes · scores 58/100 (Worth a feasibility study)about 830 ft away
- 2100 Delgany St7 stories · 90% daylit · already an apartment buildingabout 1,190 ft away
- 1999 Chestnut Pl12 stories · 91% daylit · 178 estimated homes · scores 90/100 (Strong candidate)about 1,410 ft away
A screen, not a feasibility study, from outlines and heights rather than plans: the method and how to correct a figure. If you know this building’s interior, you know what this model cannot see.