2075 N Broadway
2075 N Broadway is a 7-story apartment building in Greater Downtown Denver. Its floor plate has 99% of its area within daylight reach of a facade and scores 89 out of 100 on this screen’s measures, which is part of why it works as housing.
CO-1 · Screened 2026-09-19 · Already housing
Where 2075 N Broadway is
Its block in Greater Downtown Denver, drawn from Denver's own building outlines and street centerlines.
- Already housing
- Not screened
- 2075 N Broadway
This is already an apartment building: Denver's property records list 202 apartments here. It is on the map because the city's building outlines file it as commercial, but this site does not count it as a conversion candidate.
Across its 6 residential floors this building carries 756 sq ft of windowless core — area that must be gutted, re-plumbed and sprinklered but can never be rented as an apartment.
Modeled conversion metrics for 2075 N Broadway, 2026-09-19.
| Suitability scoreStrong candidate | 89 / 100 |
|---|---|
| Storiesfrom 86 ft aerial-survey height ÷ 12 ft floor-to-floor | 7 |
| Height bandsfloor plate by floor range, from the city's roof outlines | Floors 1–2: 18,194 sq ft · Floor 3: 14,243 sq ft · Floors 4–6: 13,934 sq ft · Floor 7: 322 sq ft |
| Floor platetypical floor, from the city outlines | 13,934 sq ft |
| Daylight efficiencyshare within 35 ft of a facade | 99% |
| Deepest interior pointviability threshold is 80 ft | 37 ft |
| Windowless coretypical floor; the building-wide total is in the text above | 27 sq ft |
| BuiltDenver does not publish a construction year with this data | — |
| ZoningFive Points | D-AS-20+ |
| Opportunity Zonenot in a 2018 designated tract | No |
The plan: window line, shape and floor rhythm
44 ft of exterior wall for each home the screen estimates — enough for two- and three-bedroom homes across the plan.
The typical floor has 693 ft of exterior wall, and across 6 residential floors the building carries 3,458 ft of it in total, divided among the 78 homes this screen estimates.
Its plate is elongated at 0.36: a slab or an L, which is why so much of the floor lies within reach of a window: the outline buys daylight that a square plan of the same area would not. How window line and plate shape are measured.
At the model’s 750 sq ft average, the plan works out at about 13.0 homes per floor. Its floors are not alike, though: the typical floor's deepest interior point is 37 ft from a facade, while its worst floor reaches 43 ft. The score follows the typical floor, so a podium that could not hold a bedroom does not by itself sink a slim tower above it — but it is there, and it is part of what would have to be drawn around.
Why 2075 N Broadway scores 89 out of 100
Daylight efficiency 100, Interior depth 100, Scale 52, Finance 77 — each out of 100, then weighted.
Score components for 2075 N Broadway. Points are the subscore times its weight.
| Component | Subscore | Weight | Points |
|---|---|---|---|
| Daylight efficiency99% of the floor area within 35 ft of a facade, scored from 40% up to 90% | 100 | 45% | 45.0 |
| Interior depthdeepest interior point 37 ft from a facade, scored from 80 ft down to 40 ft | 100 | 25% | 25.0 |
| Scale78 estimated homes, scored from 0 up to 150 | 52 | 15% | 7.8 |
| Financeremaining gap is 14% of conversion cost, scored from 60% down to 0% | 77 | 15% | 11.5 |
Most of what it earns comes from daylight efficiency, and what holds it back most is scale, at 52 out of 100: 78 estimated homes, scored from 0 up to 150.
Other buildings screened near 2075 N Broadway
The 4 closest the screen also covers, from 510 ft away. They are the colored outlines on the plan at the top of this page.
- 2180 Stout St6 stories · 96% daylit · already an apartment buildingabout 510 ft away
- 1929 Stout St22 stories · 75% daylit · 554 estimated homes · scores 69/100 (Worth a feasibility study)about 520 ft away
- 2014 California St12 stories · 87% daylit · already an apartment buildingabout 560 ft away
- 721 19th St8 stories · 100% daylit · 347 estimated homes · scores 95/100 (Strong candidate)about 600 ft away
A screen, not a feasibility study, from outlines and heights rather than plans: the method and how to correct a figure. If you know this building’s interior, you know what this model cannot see.