1850 Chestnut Pl
1850 Chestnut Pl is a 6-story apartment building in Greater Downtown Denver. Its floor plate has 95% of its area within daylight reach of a facade and scores 92 out of 100 on this screen’s measures, which is part of why it works as housing.
CO-1 · Screened 2026-09-19 · Already housing
Where 1850 Chestnut Pl is
Its block in Greater Downtown Denver, drawn from Denver's own building outlines and street centerlines.
- Already housing
- Not screened
- 1850 Chestnut Pl
This is already an apartment building: Denver's property records list 107 apartments here. It is on the map because the city's building outlines file it as commercial, but this site does not count it as a conversion candidate.
Across its 5 residential floors this building carries 4,984 sq ft of windowless core — area that must be gutted, re-plumbed and sprinklered but can never be rented as an apartment.
Modeled conversion metrics for 1850 Chestnut Pl, 2026-09-19.
| Suitability scoreStrong candidate | 92 / 100 |
|---|---|
| Storiesfrom 68 ft aerial-survey height ÷ 12 ft floor-to-floor | 6 |
| Height bandsfloor plate by floor range, from the city's roof outlines | Floors 1–2: 36,697 sq ft · Floors 3–4: 33,255 sq ft · Floors 5–6: 3,555 sq ft |
| Floor platetypical floor, from the city outlines | 33,255 sq ft |
| Daylight efficiencyshare within 35 ft of a facade | 95% |
| Deepest interior pointviability threshold is 80 ft | 37 ft |
| Windowless coretypical floor; the building-wide total is in the text above | 358 sq ft |
| BuiltDenver does not publish a construction year with this data | — |
| ZoningUnion Station | PUD |
| Opportunity Zonenot in a 2018 designated tract | No |
The plan: window line, shape and floor rhythm
38 ft of exterior wall for each home the screen estimates — enough for two- and three-bedroom homes across the plan.
The typical floor has 1,180 ft of exterior wall, and across 5 residential floors the building carries 4,286 ft of it in total, divided among the 112 homes this screen estimates.
Its plate is elongated at 0.30: a slab or an L, which is why so much of the floor lies within reach of a window: the outline buys daylight that a square plan of the same area would not. How window line and plate shape are measured.
At the model’s 750 sq ft average, the plan works out at about 22.4 homes per floor. Its floors are not alike, though: the typical floor's deepest interior point is 37 ft from a facade, while its worst floor reaches 45 ft. The score follows the typical floor, so a podium that could not hold a bedroom does not by itself sink a slim tower above it — but it is there, and it is part of what would have to be drawn around.
Why 1850 Chestnut Pl scores 92 out of 100
Daylight efficiency 100, Interior depth 100, Scale 75, Finance 72 — each out of 100, then weighted.
Score components for 1850 Chestnut Pl. Points are the subscore times its weight.
| Component | Subscore | Weight | Points |
|---|---|---|---|
| Daylight efficiency95% of the floor area within 35 ft of a facade, scored from 40% up to 90% | 100 | 45% | 45.0 |
| Interior depthdeepest interior point 37 ft from a facade, scored from 80 ft down to 40 ft | 100 | 25% | 25.0 |
| Scale112 estimated homes, scored from 0 up to 150 | 75 | 15% | 11.2 |
| Financeremaining gap is 17% of conversion cost, scored from 60% down to 0% | 72 | 15% | 10.9 |
Most of what it earns comes from daylight efficiency, and what holds it back most is finance, at 72 out of 100: remaining gap is 17% of conversion cost, scored from 60% down to 0%.
Other buildings screened near 1850 Chestnut Pl
The 4 closest the screen also covers, from 180 ft away. They are the colored outlines on the plan at the top of this page.
- 1801 Wewatta St13 stories · 86% daylit · 287 estimated homes · scores 87/100 (Strong candidate)about 180 ft away
- 1801 Chestnut Pl6 stories · 83% daylit · already an apartment buildingabout 290 ft away
- 1777 Chestnut Pl23 stories · 90% daylit · 486 estimated homes · scores 91/100 (Strong candidate)about 420 ft away
- 1900 Chestnut Pl6 stories · 97% daylit · already an apartment buildingabout 500 ft away
A screen, not a feasibility study, from outlines and heights rather than plans: the method and how to correct a figure. If you know this building’s interior, you know what this model cannot see.