100 Park Ave W
100 Park Ave W is a 20-story condominium building in Greater Downtown Denver. Its floor plate has 95% of its area within daylight reach of a facade and scores 93 out of 100 on this screen’s measures, which is part of why it works as housing.
CO-1 · Screened 2026-09-19 · Already housing
Where 100 Park Ave W is
Its block in Greater Downtown Denver, drawn from Denver's own building outlines and street centerlines.
- Already housing
- Not screened
- 100 Park Ave W
This is already a condominium building: Denver's property records list 308 condominiums here. It is on the map because the city's building outlines file it as commercial, but this site does not count it as a conversion candidate.
Across its 19 residential floors this building carries 7,871 sq ft of windowless core — area that must be gutted, re-plumbed and sprinklered but can never be rented as an apartment.
Modeled conversion metrics for 100 Park Ave W, 2026-09-19.
| Suitability scoreStrong candidate | 93 / 100 |
|---|---|
| Storiesfrom 244 ft aerial-survey height ÷ 12 ft floor-to-floor | 20 |
| Height bandsfloor plate by floor range, from the city's roof outlines | Floors 1–2: 12,449 sq ft · Floors 3–19: 8,036 sq ft · Floor 20: 1,073 sq ft |
| Floor platetypical floor, from the city outlines | 8,036 sq ft |
| Daylight efficiencyshare within 35 ft of a facade | 95% |
| Deepest interior pointviability threshold is 80 ft | 45 ft |
| Windowless coretypical floor; the building-wide total is in the text above | 389 sq ft |
| BuiltDenver does not publish a construction year with this data | — |
| ZoningFive Points | R-4 |
| Opportunity Zonenot in a 2018 designated tract | No |
The plan: window line, shape and floor rhythm
45 ft of exterior wall for each home the screen estimates — enough for two- and three-bedroom homes across the plan.
The typical floor has 359 ft of exterior wall, and across 19 residential floors the building carries 6,779 ft of it in total, divided among the 151 homes this screen estimates.
Its plate is compact at 0.78: close to a square or a circle, the most efficient envelope an office can have and the least generous one for apartments: little perimeter to divide among homes. How window line and plate shape are measured.
At the model’s 750 sq ft average, the plan works out at about 7.9 homes per floor. Its floors are not alike, though: the typical floor's deepest interior point is 45 ft from a facade, while its worst floor reaches 50 ft. The score follows the typical floor, so a podium that could not hold a bedroom does not by itself sink a slim tower above it — but it is there, and it is part of what would have to be drawn around.
Why 100 Park Ave W scores 93 out of 100
Daylight efficiency 100, Interior depth 89, Scale 100, Finance 71 — each out of 100, then weighted.
Score components for 100 Park Ave W. Points are the subscore times its weight.
| Component | Subscore | Weight | Points |
|---|---|---|---|
| Daylight efficiency95% of the floor area within 35 ft of a facade, scored from 40% up to 90% | 100 | 45% | 45.0 |
| Interior depthdeepest interior point 45 ft from a facade, scored from 80 ft down to 40 ft | 89 | 25% | 22.1 |
| Scale151 estimated homes, scored from 0 up to 150 | 100 | 15% | 15.0 |
| Financeremaining gap is 17% of conversion cost, scored from 60% down to 0% | 71 | 15% | 10.7 |
Most of what it earns comes from daylight efficiency, and what holds it back most is finance, at 71 out of 100: remaining gap is 17% of conversion cost, scored from 60% down to 0%.
Other buildings screened near 100 Park Ave W
The 4 closest the screen also covers, from 320 ft away. They are the colored outlines on the plan at the top of this page.
- 530 E 20th Ave7 stories · 100% daylit · 59 estimated homes · scores 88/100 (Strong candidate)about 320 ft away
- 2350 Cleveland Pl11 stories · 100% daylit · already an apartment buildingabout 340 ft away
- 625 E 19th Ave5 stories · 90% daylit · 297 estimated homes · scores 69/100 (Worth a feasibility study)about 390 ft away
- 480 E 20th Ave6 stories · 95% daylit · 189 estimated homes · scores 93/100 (Strong candidate)about 620 ft away
A screen, not a feasibility study, from outlines and heights rather than plans: the method and how to correct a figure. If you know this building’s interior, you know what this model cannot see.